Cable from China: the copper is the product, and it can be measured.

Nearly every cable dispute comes down to one of three things: less copper than specified, fewer metres than the drum claims, or a certificate that does not belong to your batch. All three are measurable in ten minutes with a resistance bridge, a tape measure and a cut sample — which is why cable is one of the few categories where an inspection changes the outcome almost every time.

Send your specification
Cable drums and goods checked before export from China

Home › Sourcing Map › Cable

What gets bought

Building wire

Single-core PVC insulated wire — BV solid, RV stranded — 300/500V and 450/750V, in 100-metre coils. The highest-volume, most price-compressed segment, and the one where copper shortfall hides most easily.

Power cable

PVC or XLPE insulated, 0.6/1kV and upward, single or multi-core, with or without armour. Sold on 500–1,000 m drums; the freight and handling cost is a real part of the landed price.

Control & instrumentation

Multi-core screened cable for panels and plants. Screen coverage, pairing and core identification matter more than headline price.

Specialty cable

Marine and offshore-platform, mining, nuclear-grade, LSZH and fire-resistant, photovoltaic, energy storage, EV high-voltage and robot drag-chain. China's cable cluster is one of the few places where the specialty tier is a real industry rather than a catalogue claim.

The cluster behind this — Wuwei, one of China's four largest cable bases and the only one positioned on specialty cable — is covered in the Wuhu guide. This page is about buying correctly.

The resistance table is your anti-fraud tool

Conductor resistance at 20 °C is specified by standard and cannot be argued with. These are the maximum values for plain copper conductors (IEC 60228 class 1/2); if a delivered cable measures above the table, one of three things happened — the copper is under-size, the conductor is copper-clad aluminium, or the drum holds fewer metres than stated.

Take a measured length, put a resistance bridge across it, and compare. A cheap offer that measures 20% high is not a discount — it is a different product, and the difference is copper you already paid for.

Length, drum and packaging — where the second loss hides

Drums are marked with length, and drums are not always honest. Two checks close it: weigh the drum and compare against the theoretical copper plus insulation weight for that construction, and measure resistance on the full length — resistance is proportional to length, so a 95-metre drum labelled 100 will read about 5% high even if the copper is correct.

Packaging detail that stops containers: solid-wood drums normally need ISPM 15 treatment and the mark on the wood. Plywood or steel drums avoid the question entirely, and buyers who specify them once stop worrying about it forever.

Tests worth witnessing

1 · Conductor resistance

On a measured sample length, at a recorded temperature. Compare with the table above. This is the single most useful test in the category.

2 · Insulation resistance

Measured at the specified temperature and time; a low reading points to moisture, contamination or a damaged sheath.

3 · High-voltage withstand

A few kilovolts AC applied to the finished length for a few minutes, per the standard for that voltage class. Witness it or require the test record with the serial numbers.

4 · Spark test during extrusion

Only possible if the line is running while you are there — which is one more reason to visit during production rather than after packing.

5 · Dimension and drum check

Insulation and sheath thickness on a cut sample, core identification, drum marking, and the packing list matched to physical drums. Certificates must reference your batch or contract, not the product family.

MOQ, freight and the real landed cost

Cable sells by drum or coil: building wire often in 100-metre coils, power cable on 500 or 1,000-metre drums, with factories commonly quoting a one-kilometre minimum per specification. A trial order is realistic when you buy a standard size the factory already runs; custom construction, colours or sheath compounds usually lift the minimum.

Freight is not a rounding error here — copper is heavy and drums are awkward. Compare landed cost rather than FOB price, ask for the drum dimensions and gross weights before booking, and remember that a lighter drum of the same nominal length is not good news.

Common questions

How can I tell if a cable really has the copper it claims?

Measure conductor resistance. At 20 °C, 2.5 mm² copper should not exceed about 7.41 Ω/km, 4 mm² 4.61, 6 mm² 3.08, 10 mm² 1.83. Higher than the table means under-size copper, copper-clad aluminium, or a short drum. A resistance bridge and a cut sample settle it.

What is the usual MOQ?

Cable sells by drum or coil. Building wire often 100 m coils; power cable on 500 or 1,000 m drums, frequently with a one-kilometre minimum per specification. Standard sizes are friendlier to trial orders than custom construction.

Which tests should be witnessed?

Conductor resistance, insulation resistance, a high-voltage withstand test on the finished length, a spark test if the line is running, plus insulation/sheath thickness on a cut sample and a length check against the drum marking.

Do wooden drums need treatment?

Solid-wood packing normally needs ISPM 15 heat treatment or fumigation with the mark on the wood. Plywood or steel drums avoid the issue — specify it on the order rather than discovering it at inspection.

Buying cable, drums or a specialty construction?

Send the specification — conductor, cross-section, voltage class, standard and length per drum. We will tell you which tier of the cluster actually runs it, what the realistic MOQ is, and how we would test it before your money moves.